Securin found “almost twice as many vulnerabilities as public records identified — including 20 exploited flaws that weren't even in the federal government's Known Exploited Vulnerabilities (KEV) catalog.”
Securin's Water Supply Chain Watch: scope and headline findings
The exposure management firm Securin published a new index, Water Supply Chain Watch, that analyzed 236 technology vendors selling equipment to US drinking water, wastewater, and industrial water systems. To build the index the firm compared vendor data with advisory and incident records from the US Cybersecurity and Infrastructure Security Agency (CISA), the Environmental Protection Agency (EPA), the FBI, and WaterISAC, drawing on CISA advisory data through November 20 and KEV catalog entries through November 23.
Across that dataset Securin says it identified almost twice as many vulnerabilities as are visible in public federal records, and that among these were 20 exploited flaws not present in CISA’s Known Exploited Vulnerabilities catalog.
Federal advisories, the KEV catalog, and the advisory counts
Federal reporting remains large but incomplete: the federal government has issued 4,014 security advisories for industrial control systems, while CISA’s KEV catalog lists 1,792 vulnerabilities known to have been exploited in cyberattacks. Securin also reports that federal water-tagged advisories reached their highest level this year since 2020 — a rise the firm warns is not a reliable predictor of real-world attacks.
Securin found that five vendors account for a large share of advisories tied to water systems: Rockwell Automation (58 advisories), Advantech (48), Schneider Electric (35), Siemens (26), and ABB (24). Together those five vendors account for 191 of 376 water-tagged security advisories in Securin’s index. The report flags Advantech as having the highest number of vulnerabilities rated critical, while none of the CVEs in its advisories appear in CISA’s KEV catalog.

This site is the portfolio.
OSINTSights runs on Cloudflare Workers, D1, R2, and Vectorize, with an AI pipeline on Hetzner ARM. Nubivance designed, built, and operates it. We do the same for clients.
See what we buildCompromises that didn't track with advisory volume: Unitronics and July intrusions
Securin highlights a disconnect between the advisory record and incidents observed in the wild. Unitronics generated only two water-tagged security advisories in Securin’s data, but at least 75 of its controllers were compromised between November 2023 and January 2024 by attackers exploiting default or missing passwords.
The report also cites a cluster of July intrusions security researchers suspect were the work of Iran-linked actors. Those intrusions targeted more than 100 water systems across at least 12 states and involved poorly secured internet-connected controllers — a pattern that shows successful attacks do not always depend on exploiting software bugs cataloged in advisories or KEV.
Cellular modems, exposed PLCs, and the CISA advisory
Securin reports that 791 Rockwell MicroLogix 1400 controllers across multiple US industries were exposed to the internet as of November 17. It also cites Forescout research finding that most exposed Rockwell controllers in the US — seven in 10 — sit on mobile carrier networks, where poorly secured cellular modems can provide an entry point.
A July CISA advisory described the technique seen in these incidents: “The authoring agencies observed Iranian-affiliated APT actors using several foreign-based IP addresses to access internet-facing PLCs manufactured by Rockwell Automation/Allen-Bradley, Schneider Electric, Siemens, and potentially other manufactured PLCs [T0883].” The advisory says the actors used leased, third‑party hosted infrastructure and manufacturers’ PLC programming software to connect to misconfigured victim PLCs, and that inbound malicious traffic has been observed targeting PLC devices on ports 44818, 2222, 102, and 502, as well as targeting modems on port 22.
Those cellular modems are often installed by third‑party contractors and, Securin notes, “frequently aren’t documented,” increasing the likelihood that equipment can be reached by attackers despite vendor- or patch-focused mitigation efforts.
What this means for technologists, policymakers, and water utilities
- Technologists and security teams: look beyond public advisories and KEV listings for asset discovery. Securin’s data points to exposed devices (791 MicroLogix 1400 controllers) and compromised controllers (at least 75 Unitronics units) that were successful because of misconfiguration and weak or default credentials rather than only patched software flaws.
- Policymakers and regulators: advisory volume is not a one-to-one measure of operational risk. The report documents gaps between advisories, KEV entries, and observed compromises — for example, 20 exploited flaws Securin found that are not in the KEV catalog — suggesting a need to reconcile disclosure, cataloging, and operational threat intelligence.
- Water utilities and procurement leaders: prioritize discovery of undocumented connectivity. Securin’s top recommendation for utilities is explicit: find every cellular modem in the environment (including contractor‑installed units), make sure they are not exposed to the open internet, and put a gateway with multifactor authentication in front of them — a defensive posture targeted at the modem-plus-controller attack chain that Securin’s CEO says attackers are exploiting.
“Water utilities are spending time and money fixing the vulnerabilities they're told to worry about,” Securin CEO Srinivas Mukkamala said. “Meanwhile, attackers are getting in through equipment nobody knew was connected or passwords nobody bothered to change.” The index makes a clear, data-driven case that discovery and inventory — not only patching known CVEs — must be central to water-sector cyber risk reduction.